TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic

Technical Service Department.

• Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-

nel.

• This brewer is heated at all times. Keep away from combustibles.

WARNING – • Exercise extreme caution when servicing electrical equipment.

• Unplug the brewer when servicing, except when electrical tests are specified.

• Follow recommended service procedures

• Replace all protective shields or safety notices

PROBLEM

Water is not hot

Spitting or excessive steaming

PROBABLE CAUSE

1. Limit Thermostat

CAUTION - Do not eliminate or

bypass limit thermostat/thermal

cut-off. Use only BOM replace-

ment part.

Limit Thermostat - #29329.0001

2. Control Thermostat

3. Tank Heater

1. Lime Build-up

CAUTION - Tank and tank com-

ponents should be delimed

regularly depending on local

water conditions. Excessive min-

eral build-up on stainless steel

surfaces can initiate corrosive

reactions resulting in serious

leaks.

2. Control Thermostat

REMEDY

Refer to Service - Limit Thermo-

stat for testing procedures. See

page 10

Refer to Service - Control Ther-

mostat for testing procedures.

See page 9

Refer to Service - Tank Heater for

testing procedures. See page 10

Inspect the tank assembly for

excessive lime deposits. Delime

as required.

Refer to Service - Control Ther-

mostat for testing procedures.

See page 9

39064 042806