Location:

The control thermostat is located inside the hood

on the left end of the mounting bracket.

Test Procedures:

1. Disconnect the brewer from the power source.

2. Locate the black wire on the control thermo-

stat.

3. Check voltage across the black wire on the control

thermostat and the white wire on the tank heater

with a voltmeter. Plug-in the brewer to the power

source. The indication must be 120 volts ac.

4. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the wiring

diagram and check the brewer wiring harness.

5. Locate the blue/black wire on the control ther-

mostat.

6. Gently remove the capillary bulb and grommet

from the tank.

7. Check voltage across the blue/black wire of the

control thermostat and the white wire on the

tank heater with a voltmeter when the control

thermostat is turned "ON" (fully counterclockwise

for thermostat with tee handle control or fully

clockwise for thermostats with control knob).

Plug-in the brewer to the power source. The

indication must be 120 volts ac.

Voltage must not be present across these terminals

when the thermostat is turned "OFF" (fully counter-

clockwise).

8. Disconnect the brewer from the power source.

If voltage is present as described, reinstall the capillary

tube into the tank to the line 4.5" above the bulb, the

control thermostat is operating properly.

If voltage is not present as described, replace the

thermostat.

SERVICE (cont.)

Removal and Replacement:

1. Remove wires from control thermostat leads or

terminals.

2. Remove the thermostat capillary bulb by firmly

pulling-up on the capillary at the tank lid. This

will disengage the grommet from the tank lid.

P1252

FIG.4 CONTROL THERMOSTAT TERMINALS

BLK to Terminal Block

BLU/BLK to

Limit Thermostat

or Thermal Cut-Off

3. Remove two #8-32 screws securing the control

thermostat to the mounting bracket inside the

hood.

4. Slide the grommet to the line 4.5" above the bulb

on the new capillary tube.

5. Insert the capillary bulb through the hole in the

tank lid and press the grommet firmly and evenly

so that the groove in the grommet fits into the

tank lid.

6. Carefully bend the capillary tube so that the tube

and bulb inside the tank are in the vertical posi-

tion.

NOTE - The capillary tube must be clear of any electri-

cal termination and not kinked.

7. Using two #8-32 screws secure the control

thermostat to the mounting bracket inside the

hood.

8. Refer to Fig. 4 when reconnecting the wires.

9. Adjust the control thermostat as required

39064 042806