Electrical installation − ems version, Inductive, E84dx – Lenze 8400 protec Manual User Manual
Page 120: E84d x... f

Electrical installation − EMS version
Devices in a power range of 0.75 ... 4 kW (3/PE AC 400 V)
Example circuits
l
120
EDS84DPS424 EN 5.0
Inductive
M
3~
U
V
W
+
+
BRK1
T1
T2
T
h
+
-
"
"
0
"
"
6
4
1 2 3
X21
+
c
1
2
3
a
5
M
3~
U
V
W
+
+
T1
T2
T
h
BRK1
+
-
~
~ S1 S2
GL1
1
E84Dx...
5
8
4
6
1 7 3
X21
+
1 2
X20
+
X80
X43
X42
X41
X32
X31
+
1
11
2 3 4
12
+
X10
1
11
2 3 4
12
+
X11
+
-
+24 V
GND
U24
=
X46
X47
X48
X45
X81
X82
X34
BRW1
1 2
+
"
E84D x...
F
2 DC
560 V
+
-
+UG
-UG
PE
+
-
2 DC
24 V
+
-
Power
Data
E84DWSP060_D
E84DFx...
8400 protec EMS controller, inductive system
X10: +UG, −UG, PE
560 V DC (mains voltage)
X10: +, −
24 V DC (motor holding brake)
X11
Mains voltage loop−through technique (optional)
X31 ... X32
Fieldbus communication
X34
CANopen master PLC
X41 ... X43
DIO
X45 ... X48
EMS: Further DIO
X80
SSI
X81/X82
EMS: RS485/422
M
Motor
0
Motor connection system: Plug type Q8/0
1
Motor connection system: Plug type Modular
T
h
PTC thermistor (PTC) or thermal contact (NC contact)
BRK1
Spring−applied brake
GL1
Spring−applied brake control
BRW1
External brake resistor at the optional terminal X20
U24
Supply voltage 24 V internal