Technical data, 790 v, adjustable – Lenze 8400 protec Manual User Manual

Page 52

Advertising
background image

Technical data

Rated data
Operation at a rated mains voltage of 500 V

4

l

52

EDS84DPS424 EN 5.0

Rated data for internal brake chopper

Switching threshold V

BRmax

: 790 V, adjustable

R

Bmin

[

W]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type

Internal brake resistor

E84Dxxx7514
E84Dxxx1524

220

3.6

2.8

0.5

0.05

1)

−

−

−

E84Dxxx3024
E84Dxxx4024
E84Dxxx7524

−

−

−

−

−

−

−

−

External brake resistor

E84Dxxx7514

150

5.3

4.2

1.4

1.2

300

60

−

E84Dxxx1524

150

5.3

4.2

2.9

2.5

300

60

−

E84Dxxx3024

47

16.8

13.3

5.7

4.9

300

60

−

E84Dxxx4024

47

16.8

13.3

14.1

12.2

300

60

−

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS − important for the dimensioning of the cables

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time

t

Z

− t

on

Recovery time

t

fp

Maximum running time without initial load and compliance with the recovery
time

1)

Max. heat Q

B

: 3 kWs

Max. power loss in the internal brake resistor P

Bdav

: see table

f

ch

I

a

P

Bdav

[W]

[kHz]

[A]

T

amb

20 °C

30 °C

40 °C

45 °C

E84Dxxx7514

4

1.9

50

47

−

27

1.14

50

41

−

21

8

1.9

48

34

21

−

1.14

36

23

10

−

E84Dxxx1524

4

3.1

42

28

−

8

1.86

50

47

−

27

8

3.1

22

9

0

−

1.86

48

34

21

−

f

ch

Output switching frequency

I

a

Motor current

P

Bdav

Permissible power loss in the internal brake resistor, averaged over 60 s and
dependent on T

amb

(Linear interpolation/extrapolation via T

amb

is permissible. Here, the

application must limit the power loss in the brake resistor to P

Bdav

£ P

Bd

.)

T

amb

Ambient temperature

Advertising