Diagnostics
11.1
LED status displays
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
BE
red
off
No fault
blinking
The configuration is invalid/faulty.
blinking once
(single flash)
• A non requested state change has occurred. (The slave
application has autonomously changed the EtherCAT status.)
• Synchronisation error (The EtherCAT node automatically changes
to the "Safe-operational" state.)
blinking twice
(double flash)
An "Application Watchdog Timeout" or a "Sync Manager Watchdog
Timeout" has occurred.