2 technical data, General data and operating conditions, Technical data – Lenze E94AZEX100 User Manual
Page 26: 2technical data

2
Technical data
General data and operating conditions
EDK94AZEX1 DE/EN/FR/ES/IT 3.1
26
l
H1_Daten−Abmess1
2
Technical data
General data and operating conditions
Standards
Conformity
CE
Low−Voltage Directive (73/23/EEC)
Approval
UL 508C
Power Conversion Equipment (file no. 132659)
Protection
Enclosure
EN 60529
IP 20
NEMA 250
Protection against accidental contact acc. to type 1
Insulation resistance
EN 61800−5−1
Overvoltage category III
Reduction from 2000 m: Overvoltage category II
Environmental conditions
Climate
Storage
IEC/EN 60721−3−1
1K3 (−25 ... +60 °C)
Transport
IEC/EN 60721−3−2
2K3 (−25 ... +70 °C)
Operation
IEC/EN 60721−3−3
3K3 (−10 ... +55 °C)
Power derating at +45 ... +55 °C: 2.5 %/°C
Site altitude
0 ... 4000 m amsl
Power derating at 1000 ... 4000 m amsl: 5 %/1000 m
Pollution
EN 61800−5−1
Pollution degree 2
Vibration resistance
Germanischer
Lloyd
General conditions: acceleration resistant up to 0.7 g