Connection data, Electrical installation – Lenze E94AZHA0051 User Manual

Page 39

Advertising
background image

Electrical installation

Connection data

4

EDKE94AZHA DE/EN/FR/ES/IT 1.0

39

l

H1_E_INST−−−−(DUMMYSEITEVOR)−−−

Connection data

Terminal X107

Labelling

Description

Terminal for the motor holding brake

BD1
BD2

+ (Lenze: WH)
− (Lenze: BN)
E94AZHx0051: 24 V DC, max. 2.5 A
Observe correct polarity!

+ / −

Supply voltage for the motor holding brake
(18 ... 30 V DC)
Observe correct polarity!

SSP940X107

Terminal data

Conductor cross−section

Tightening torque

[mm

2

]

[AWG]

[Nm]

[lb−in]

Single core

0.25 ... 2.5

24 ... 12

0.5 ... 0.6

4.4 ... 5.3

2 conductors

1)

0.25 ... 1.5

24 ... 16

1)

Two conductors of the same cross−section with a twin wire end ferrule

Advertising