Connection data, Electrical installation – Lenze E94AYAB − SM100 User Manual
Page 27
Electrical installation
Connection data
EDK94AYAB DE/EN/FR/ES/IT 5.0
27
l
H1_E_INST−Austausch_VB_VC
Connection data
X80
Marking
Description
Electrical data
SIA
Input first shutdown path
SIA: I
typ
= 160 mA
GI
GND potential for SIA/SIB
LOW: −3 ... 5 V,
HIGH: 15 ... 30 V,
SIB
Input second shutdown path
SIB: I
typ
= 28 mA
Supply through safely
separated power
supply unit
(SELV/PELV)
GO
GND potential feedback
24 V, max. 0.7 A,
short−circuit−proof,
LOW−active,
Supply through safely
separated power
supply unit
(SELV/PELV)
24O
24 V supply feedback
SSP9400X80
DO1
Non−safe signalling output: "Safe
pulse inhibit"
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Rigid
0.2 ... 2.5
24 ... 12
Spring terminal
Wire end ferrule,
insulated
0.2 ... 1.5
24 ... 16
Twin wire end
ferrule
0.5 ... 1.0
20 ... 18
Stripping length / contact length: 10 mm
Information for the exchange of modules of different hardware versions
up to HW: VB
from HW: VC
Comment
SI1
SIA
The exchange of the spring
terminal is required!
GI
GI
SI2
SIB
GO
GO
24O
24O
DO1
DO1