Rated data, Technical data – Lenze E94AZHY0026 User Manual
Page 33

Technical data
Rated data
EDK94AZHY26 DE/EN/FR/ES/IT 1.1
33
l
H1_Daten−BemDat_82WBRE_DE
Rated data
Input data
Voltage
Frequency
Current [A]
Number
of
phases
Type
[V]
[Hz]
max. +45 °C
max. +55 °C
E94AZHY0026
400/500
50/60
0.61/0.61
0.61/0.61
1
Temperature in the control cabinet
Output data
Voltage
Frequency
Current [A]
Number
of
phases
Type
[V]
[Hz]
max. +45 °C
max. +55 °C
E94AZHY0026
180/225
0 (DC)
0.61/0.61
0.61/0.61
1
Temperature in the control cabinet
Area
Values
Input voltage
AC 400 V (320 ... 550 V), 45 ... 65 Hz
Output voltage
DC 180 V
With mains voltage of AC 400 V
Brake current
0.1 ... 0.61 A
Cable protection
Recommendation: 5 A, tripping characteristic "B" or "C"
Control input
Control voltage
Internal
Control current
Protective function
Max. connectable cable
cross−section
2.5 mm
2
AWG 12
Maximum cable length
150 m