Electrical installation
Assignment of the terminals
EDK10201EZ3 DE/EN/FR 5.1
16
l
H1_E_INST−Belegung_10201_en
Terminal
Signal type
Function
Technical data
Remarks
X1/
^
24
−
GND, reference potential
X2/+O24
−
DC supply voltage
18 VDC ... 30 VDC
Connected via
emergency off at the
Drive PLC
X2/VBr
−
DC supply voltage for
X3/O9, X3/O10
18 VDC ... 30 VDC
Always conduct via
emergency off
X3/O5
Digital
outputs
LOW (0 V ... +4 V)
HIGH (+13 V ... +30 V)
Load capacity: max. 1 A
X3/O6
X3/O7
X3/O8
X3/O9
LOW (0 V ... +4 V)
HIGH (+13 V ... +30 V)
Load capacity: max. 2 A
Suitable for brake
control
X3/O10
X4/I9
Digital
inputs
LOW (0 V ... +4 V)
HIGH (+13 V ... +30 V)
Input current: max. 8
mA at 24 V
X4/I10
X4/I11
X4/I12
X4/I13
X4/I14
(
Stop!
ƒ
Ensure a sufficient dimensioning of the DC voltage supply, if the loads are
connected to the digital outputs.
ƒ
The extension board must exclusively be supplied separately.The internal
supply via the Drive PLC is not permissible.