Change/Save parameters

MA9371BB 2.0

- 5 -

Change parameters

1. Change from the menus to the code level using the arrow keys

z

,

y

,

Y

or

Z

.

”Code” is displayed.

2. Select output AIN2/OUT (selection number 55) using

z

or

y

select code or

subcode.

3. Change to the parameter level using PRG.”Para” is displayed.
4. Select output AIN2/OUT (selection number 55) using

Y

or

Z

move the cursor

(small, black bar) under the number to be changed.

5. Select output AIN2/OUT (selection number 55) using

z

or

y

change number.

6. Repeat 4. and 5. to change other numbers, if ncessary.
7. Accept parameters. The way of accepting the changed parameterr is displayed in

front of the parameter:

Display in front of the parameter Controller uses the new value

p

immediately, during the change

SH+PRG

p

after pressing

T

+

V

.

Acknowledgement: ok in the display

SH+PRG

Press

S

to inhibit the controller.

Press

T

+

V

.

Acknowledgement: ok in the display
Press

U

to enable the controller.

8. Press

V

twice to go to the code level. ”Code” is displayed.

You can establish a user menu with max. 32 codes which you use
frequently under C0517.

•

The number before the comma is the code number.

•

The number after the comma is the subcode.

•

Code-subcode combinations are allowed only once.

Save parameter set

You have to save the modified parameters if you do not want to loose them after mains
disconnection.

•

You can establish up to four parameter sets, e.g. if you process different materials
on a machine or if this is required by different operating states (setup mode,
”stand-by”).

•

If you need only one parameter set, save the modifications permanently under
parameter set 1, since the controller automatically loads parameter set 1 after
mains connection.

How to proceed

1. Change from the menus to the code level using the arrow keys.

”Code” is displayed.

2. Select output AIN2/OUT (selection number 55) using

z

or

y

select C0003.

3. Change to the parameter level using PRG.

”Para” is displayed.

4. Set parameter to 1 using

z

or

y

(also possible during operation).

Note: If the parameter set is to be saved under another number, select 2, 3, or 4
instead of 1.

5. Press

T

+

V

.

”OK” is displayed for approx. 1 s.
Now your settings are saved permanently under parameter set 1 (or 2, 3. 4).

Further information on parameter setting can be obtained from the
corresponding Operating Instructions for the controller.