L_CanDSxClose − Deactivation of index mapping

3−5

L

LenzeCanDSxDrv.lib EN 1.2

3.4

L_CanDSxClose − Deactivation of index mapping

Function

This function is used to deactivate the mapping table and the redirection of indeces.

·

For deactivation, the transfer parameter bClose must be set to TRUE.

·

After this function has been executed, the indeces accessed via the system bus interface will
no longer be redirected to the corresponding codes of the mapping table.

Declaration

BOOL

L_CanDSxClose (bClose);

Transfer parameters

Data type

Information/possible settings

bClose

Bool

Deactivation of index redirections according to the mapping table.

TRUE The CanDSx driver is deactivated in the operating system.

Return value

Data type

Value/meaning

Bool

Status

TRUE The CanDSx driver has been deactivated in the operating system.

FALSE The CanDSx driver has not been deactivated in the operating system.

·

Remedy: Call the function with transfer parameter bClose = TRUE.

Note!

If the function L_CanDSxClose is called while code read or write requests are active an error may
occur!

This is why all actions with code access should be completed before this function is called.

Example

Calling the function in ST:

IF bCloseCanDSxDriver AND NOT bClose THEN
bClose :=

TRUE;

dwReturnClose :=

L_CanDSxClose(bClose:= TRUE);

END_IF