LenzeFpiDrv.lib function library

Functions

3.3

Send data (L_Rs232SendData)

3−4

L

LenzeFpiDrv.lib EN 1.1

3.3

Send data (L_Rs232SendData)

INT.

L_Rs232SendData (wDrvNr, pabySendDataMemory, wNumberOfBytes)

With this function data can be send via the FP interface.

·

The operating system of the controller sends data and executes the PLC program at the same
time, i.e. a byte can be sent every max. 250

ms.

·

A max. of 32767 characters can be send per function call.

·

A new call is only possible after the previous call has been processed, i.e. after all data has
been send.

·

An active sending process can be cancelled by repeating the function L_Rs232Open. It is
then possible to receive data which have been changed.

L_Rs232SendData

wDrvNr
pabySendDataMemory
wNumberOfBytes

Fig. 3−3

Send data (L_Rs232SendData)

Transfer parameter

Identifier

Data type

Possible settings

Info

wDrvNr

Word

30

AIF interface

pabySend
DataMemory

Pointer to Array

of Byte

Pointer set onto the address in
the memory where the data
bytes to be sent are stored.

The address of a variable (e. g. data array) can be detected using
the address function ADR.

wNumberOfBytes

Word

1 ... 32767

Number of data bytes to be sent

Feedback value

Data type

Value

Meaning

Priority

Integer

−4

Pointer of send memory does not point to PLC−RAM.

4

−3

Number of bytes to be sent exceeding its limits (1 ... 32767).

3

−2

Send order not passed on to the operating system since the previous send order is not
completed yet.

2

−1

Wrong driver number (wDrvNr) or driver not initialised.

1

Note: If errors are caused by several problems, the error cause with the highest priority sends back the

corresponding feedback value.

0

Send order successfully transferred to operating system.

Tip!

Sending is executed at the same time as the PLC program.

Please ensure that all send orders are completed before calling up this function, otherwise an error
will occur (feedback value = −2).