Technical data

Rated data

EDKRBM001 DE/EN/FR 5.0

36

l

H1_Daten−Abm_BF3_BL

Rated data

Electrical data

R

B

P

d

Q

B

U

max

[

W

]

[W]

[kWs]

[V

DC

]

ERBM052R200W

52

200

30.0

800

ERBM082R150W

82

150

22.5

ERBM082R200W

200

30.0

ERBM100R150W

100

150

22.5

ERBM200R100W

200

100

15.0

ERBM240R200W

240

200

30.0

ERBM370R150W

370

150

22.5

ERBM470R050W

470

50

7.5

ERBM470R100W

100

15.0

R

B

Resistance

P

d

Permanent power

Q

B

Heat quantity

U

max

Max. operating voltage

Temperatures

T

nom

T

TK

T

max

[°C]

On the surface

150

250

500

On the clearance
edge

*)

90

100

120

T

nom

Maximum temperature for rated data

T

TK

Temperature at which the thermal contact is activated

T

max

Maximum temperature in the case of improper use

*)

Measured for air as the ambient medium (small coefficient of
thermal conductivity); if materials which heat up are located
at the clearance edge (greater coefficient of thermal
conductivity), the temperature continues to rise.