Detail a1 | simple torque and velocity system, Detail a2 | input power connections, Servo motor – Lenze SQF01C User Manual

Page 2

Advertising
background image

Detail A1 | Simple Torque and velocity system

MB+/DIR+

MA-/STEP-

MA+/STEP+

N/C

Encoder power

COM

Encoder Z-

Encoder Z+

Encoder B-

Encoder B+

Encoder A-

Encoder A+

ENABLE-

Ready Out-C

+5V 20ma

COM

REF+

REF-

MB-/DIR-

Ready Out-E

Aux Out-E

Aux Out-C

ACOM

ENABLE+

Shield

13

25

12

24

11

23

10

22

9

21

8

20

7

19

6

18

5

17

4

16

3

15

2

14

1

HALL B+

Encoder power

HALL C-

HALL A+

HALL A-

HALL B-

HALL C+

Encoder Z+

Shield

Encoder B-

Encoder B+

Encoder Z-

Encoder A+

COM

Encoder A-

DB15

TB504

8

15

7

14

6

13

5

12

4

11

3

10

2

9

1

COM

RS-232 TX

RS-232 RX

DB9

TB505

5

9

4

8

3

7

2

6

1

W

V

U

Servo
Motor

Hall Sensors
and Encoder

-10V

REF-

REF+

+10V

AGND

MA+/STEP+

MA-/STEP-

MB+/DIR+

MB-/DIR-

Analog Output

Aux Input

ENABLE

Ready Output

Aux Output

COM

TB502

15 Pin Terminal

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

Line Driver

+5V

26LS31

V(S)

U(R)

DUMP-

DUMP+

W(T)

GND

TB501

9 Pin Terminal

DB25

TB506

40 Ohm 100W

Dump Resistor

MOTION

CONTROLLER

1

2

3

4

5

6

INPUT POWER CONNECTION

(See detail A2)

PC COMPUTER

Detail A2 | Input power connections

TB501-8 Pin

SINGLE PHASE

AC SERIES

GND

L1

L2

6

7

8

THREE PHASE

AC SERIES

TB501-9 Pin

L1

GND

L2

L3

6

7

8

9

SSxxx-3P Systems Only

DC SERIES

TB501-8 Pin

GND

DC+

DC-

6

7

8

Hazard of electrical shock! Circuit potentials are

at 115 VAC or 230 VAC above earth ground. Avoid

direct contact with the printed circuit board or with

circuit elements to prevent the risk of serious injury

or fatality. Disconnect incoming power and wait 60

seconds before servicing drive. Capacitors retain

charge after power is removed.

DO NOT connect incoming power to the output

motor terminals (U, V, W)! Severe damage to the

drive will result.

Advertising