Lenze MHERA Three-phase AC motors User Manual

Page 16

Advertising
background image

MA 33.0005 DE/EN/FR/IT/ES 5.0

16

KFZ_Zeichen_EN-anschluss-stillstandheizg

Connection of feedback system

Resolver
Terminal

Designation

Meaning

B1

B2

+ Ref

- Ref

Transformer windings (reference

windings)

B3

not assigned

B4

B5

+ Cos

- Cos

Stator winding cosine

B6

B7

+ Sin

- Sin

Stator winding sine

B8

not assigned

Incremental encoder / sin/cos absolute value encoder with Hiperface
Terminal

Designation

Meaning

B1

B2

+ U

B

GND

Supply +

Mass

B3

B4

A / + COS

A / Ref cos

Track A / process data channel

Track A inverse / process data channel

B5

B6

B / - SIN

B / Ref sin

Track B / process data channel

Track B inverse / process data channel

B7

B8

Z / data +

Z / data -

Zero track / parameter channel + RS485

Zero track inverse / parameter channel - RS485

B10

1)

Shield - housing

Shield - incremental encoder

1) The terminal is not assigned if insulation at N-end shield of the motor has been selected!