Sd12: Error thermal detector MultiEncoder [xx.0119.00022]

oC5: Ixt overload [xx.0119.00050]

ot1: Maximum torque reached [xx.0123.00001]

oC7: Motor overcurrent [xx.0123.00007]

Response (Lenze setting printed in bold)

Setting:

C00583/6

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The signals of the encoder connected to the encoder

interface are outside the defined operating range of the

motor temperature detection.

• Check contacts of the encoder cable at the motor and

controller.

• Check the selected motor temperature sensor in

C01190/2

as to whether it complies with the

assembly in the motor.

• If required, switch off thermal sensor monitoring

(

C00583/6

="0").

Response (Lenze setting printed in bold)

Setting:

C00604

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The Ixt overload check has tripped.

• Operating threshold = 100 % Ixt (adjustable in

C00123

)

Possible causes:

• Wrong dimensioning of the device with regard to its

motor load.

• Load cycles are not complied with.

• Check and, if required, correct dimensioning of the

device and the motor load with regard to technical

data.

• Reduce motor load cycles (observe load cycles

according to documentation).

Response (Lenze setting printed in bold)

Setting:

C00608

( Adjustable response)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

The device indicates that the maximally possible torque

at the motor shaft has been reached.

•

C00057

displays the current torque.

Reduce motor load.

Response (Lenze setting printed in bold)

0: No Reaction  1: Fault  2: Trouble  3: TroubleQuickStop  4: WarningLocked  5: Warning  6: Information

Cause

Remedy

Maximum current monitoring has tripped.

• The instantaneous value of the motor current has

exceeded the limit value set in

C00939

.

Check and, if required, correct dimensioning of the load

with regard to the installed device power.