4 parameter setting & configuration, 1 basic signal flow, Parameter setting & configuration – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual
Page 16: 9400 technology applications | actuator – speed, 4parameter setting & configuration

9400 Technology applications | Actuator – speed
Parameter setting & configuration
Basic signal flow
16
L
EDS94TA10010xxxx EN 1.1 - 10/2008
4
Parameter setting & configuration
4.1
Basic signal flow
[4-1]
Signal flow of the TA "Actuator – speed" (schematic diagram)
Speed setpoint conditioning
Setpoint gain
Selection of analog input/fixed setpoints
Setpoint inversion
Ramp generator
Basic drive functions
Speed follower
Manual jog
Quick stop
Stop
Brake control (optional)
!
Limiter (optional)
3
0
2
4
LS_ManualJog
n
t
и
з
6
7
8
LS_Brake
n
t
LS_Limiter
n
t
LS_Quickstop
STOP
9
1
5
Gain
Invert setpoint
Selection
LS_Speed...
M
Speed
setpoint
n
t
LS_Stop
internal
status machine
DI2
DI6
DI7
DI8
DI1
DI3
DI4
OUT
IN
Ramp generator
%
1
%
2
%
15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
Basic drive functions
AIN1
и
з
M
v