3 speed ramp generator, 9400 technology applications | actuator – speed – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual
Page 21

EDS94TA10010xxxx EN 1.1 - 10/2008
L
21
9400 Technology applications | Actuator – speed
Parameter setting & configuration
Speed setpoint conditioning
4.3.3
Speed ramp generator
[4-5]
Ramp generator (schematic diagram)
In order to avoid setpoint step-changes the speed setpoint passes a ramp generator with a
parameterisable acceleration/deceleration and S-ramp time before it is transmitted to the
basic drive function "Speed follower".
r
Parameter setting: Tab Application parameters dialog level Overview
Gain
Invert setpoint
Selection
LS_Speed...
M
Speed
setpoint
DI2
DI3
DI4
OUT
IN
Ramp generator
%
1
%
2
%
15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed setpoint
AIN1
M
v
Parameter
Lenze setting
Value Unit
C03502
Basic acceleration time
1.000 s
C03503
Basic deceleration time
1.000 s
C03504
Basic S-ramp time
0.100 s
C03510
Profile mode
Linear ramps