12 parameterisable function blocks, 1 l_devapplerr1, 2 l_tbdelay1 – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual
Page 34: 9400 technology applications | actuator – speed

9400 Technology applications | Actuator – speed
Parameter setting & configuration
Parameterisable function blocks
34
L
EDS94TA10010xxxx EN 1.1 - 10/2008
4.12
Parameterisable function blocks
This subchapter lists all relevant parameterisable function blocks of the technology
application and the corresponding parameters in alphabetical order.
4.12.1
L_DevApplErr1
4.12.2
L_TbDelay1
Is an instance of
Function
L_DevApplErr
Error handling
Application error messages (C 33)
Parameter
Possible settings
Information
C05900
980
999 Module ID
C05901/1...8
0
65535 Error ID
C05902/1...8
Error response
0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information
Is an instance of
Function
L_TbDelay
Delay of the signal MI_bSpeedCtrlLimited for error handling
Parameter
Possible settings
Information
C03550
Selection of the edge to be delayed
0 Rising edge
Lenze setting
1 Falling edge
2 Both edges
C03551
0.000
s
60.000 Delay time
• Initialisation: 0.100 s