2 speed ramp generator, 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual
Page 18

9400 Technology applications | Actuator – torque
Parameter setting & configuration
Speed limit value conditioning
18
L
EDS94TA10020xxxx EN 1.1 - 10/2008
4.5.2
Speed ramp generator
[4-7]
Ramp generator (schematic diagram)
In order to avoid setpoint step-changes the speed limit value passes a ramp generator with
a parameterisable acceleration and deceleration time before it is transmitted to the basic
drive function "Torque follower".
r
Parameter setting: Application parameters tab dialog level Overview
Offset
Selection
LS_Torque...
M
Torque
setpoint
DI2
DI4
OUT
IN
Ramp generator
%
1
%
2
%
15
Fixed setpoints
Status
machine
(basic drive
functions)
Speed limit
AIN2
M
v
F
Parameter
Lenze setting
Value Unit
C03502
Basic acceleration time
1.000 s
C03503
Basic deceleration time
1.000 s
C03010
Profile mode
Linear ramps