12 application error messages, 9400 technology applications | actuator – torque – Lenze E94AxHE Technology Application Actuating drive - Torque User Manual
Page 29

EDS94TA10020xxxx EN 1.1 - 10/2008
L
29
9400 Technology applications | Actuator – torque
Parameter setting & configuration
Application error messages
4.12
Application error messages
For the output of application-specific error messages an FB instance L_DevApplErr1 of the
function block L_DevApplErr is available.
r
Via the 8 boolean inputs up to 8 different application error messages with
parameterisable module ID, error ID and error response can be activated by the
application.
r
Parameter setting: All parameters tab
Reset of error message
In the Lenze setting the digital input DI5 for resetting (acknowledging) an error message is
connected to the input DI_bResetError1 of the drive interface.
Error message
Error ID
Error response
1
Torque follower in limitation
8001
Warning locked
2
-
8000
Error
3
-
8000
Error
4
-
8000
Error
5
-
8000
Error
6
-
8000
Error
7
-
8000
Error
8
-
8000
Error
Parameter
Lenze setting
C05900
Module ID
980
C05901/1...8
Error ID 1 ... 8
See table above
C05902/1...8
Error response 1 ... 8
See table above