Short setup
Step 5: Controlling applications via terminals
4.7
Step 5: Controlling applications via terminals
Terminal assignment
Procedure
1. Enable controller: Set digital input RFR to HIGH level.
2. Deactivate quick stop: Set digital input DI1 to HIGH level.
Terminal
Assignment (Lenze setting)
X5
RFR
Controller enable
DI1
Quick stop
• If DI1 is set to LOW level, the drive is decelerated to standstill within the deceleration
time set for the quick stop function independent of the setpoint selection.
• If the quick stop function is deactivated, the drive is led to the selected setpoint again via
the set acceleration time.
DI2
Connection of reference switch
DI3
-
DI4
Close clutch
DI5
Reset error
• By means of a LOW-HIGH edge an existing error status can be reset if the cause of the
fault is removed.
DI6
-
DI7
-
DI8
-