2 machine parameters, 9400 technology applications | electronic gearbox – Lenze E94AxHE Technology Application Electronic gearbox User Manual
Page 37

EDS94TA10030xxxx EN 1.2 - 11/2009
L
37
9400 Technology applications | Electronic gearbox
Parameter setting & configuration
Machine parameters
5.2
Machine parameters
The following schematic diagram shows the relevant global data (machine parameters) for
the interconnection via the electrical shaft:
[5-2]
Schematic diagram of the most important machine parameters
Detailed information for setting the machine parameters can be obtained from the
following subchapters.
n
Master axis (here: master value encoder as real master)
o
Slave axis 1
p
Slave axis 2
q
Digital frequency cascade (digital frequency extension module required)
d
d
1
3
i
1
i
3
l
1
v
max
d
2
i
2
Slave
Master/Slave
Digital
frequency
Symbol
Description
i
1
Gearbox ratio of master value encoder
d
1
Diameter of the master roll
l
1
Master value cycle (if available)
v
max
Maximum speed
i
2
, i
3
Gearbox ratio of the slave axes
d
2
, d
3
Diameter of the slave rolls