(8) Adjusting dial

If the parameter indicator lights up, then the selected parameter can be altered on adjusting dial.

Available parameters where 2T and 4T mode have been selected:

PF Gas pre-flow time

Unit Seconds

Setting range 0.1—1

Factory setting 0.3

SA Starting current (only with 4T)

Unit Amps

Setting range 5—100% of main current WC (DC);10—100%of main current WC (A/C)

Factory setting 5

UPS Upslope time

Unit Seconds

Setting range 0—10

Factory setting 0

WC Welding current

Unit Amps

5—200 (TIG-DC);10—200 (TIG-AC); 5—170 (Stick-DC);10—170 (Stick-AC)

BC Base current

Unit Amps

5—200 (DC);10—200 (AC)

Important! Only selectable when “pulse key” has been pressed.

PW Pulse Width

Unit %

Setting range 5—100

Factory setting 5

Important! Only selectable when “pulse key” has been pressed.