Tig welder – Longevity TIGWELD 200 EX User Manual

Page 15

Advertising
background image

TigWeld 200EX 200amp AC/DC

TIG Welder

~ 15 ~

PF Pulse frequency

Unit Hz

Setting range 0.5—200

Factory setting 0.5

Important! Only selectable when “pulse key” has been pressed.

DS Downslope time

Unit Seconds

Setting range 0—10

Factory setting 0

AC Arc current (only with 4T)

Unit Seconds

Setting range 5—100% of main current WC (DC);10—100% of main current WC (AC)

Factory setting 5

PF Gas post-flow time

Unit Seconds

Setting range 0.1—10

Factory setting 3

AC frequency (only with TIG-AC)

Unit Hz

Setting range 50—250 (WC<50A)

50—200 (50A≤WC<100A)
50—150 (100A≤WC<150A)

50—100 (150A≤WC<200A)

Balance (only with TIG-AC)

Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as

Aluminium, Magnesium and its alloy) while in AC output mode.

Unit %

Setting range 15—50

Factory setting 15

(9) Rod electrode (Stick) welding key

Parameter Setting range

Arc force 0-10

Hot start 0-10

Arc length 0-10

Advertising