Troubleshooting – Longevity FORCECUT 50i User Manual

Page 33

Advertising
background image

Plasma Cutters www.LWELD.com

www.longevity-inc.com

29

Troubleshooting

If your unit is not properly functioning, please call us immediately toll free at 1-877-
566-4462 for support. We have included a small table here to diagnose most
common problems.

Problems, Causes, and Solutions

Problems

Causes/

Solutions

Machine will not
turn on.

Check cords and breaker. If nothing is found, contact

LONGEVITY

The machine runs,
but nothing is
happening

Check to see if you have the air regulator to the correct

pressure. Make sure the regulator adjustment knob is turned
clockwise and allow pressure. Check the consumables and make
sure they are properly assembled. Check the ground clamp and
proper grounding to the unit. Check pilot arc wire to insure it is
properly connected to the unit.

Consumables
(tips) are being
consumed

Improper air flow. Increase the PSI on the regulator, check for

leaks in the hose, maintain a distance of 1/8” from the torch tip or
workpiece. If your unit comes with a manual Post Flow 2.5 or 5.0
switch make sure you leave it on 5.0 for more air to pass cooling
your torch tips.

Heavy Underside
Slag (Cutting)

Slow travel speed. Increase travel speed or amperage on unit.

Poor Cut Quality

Check Air Pressure. Insure your unit is capable of cutting the

desired thickness of material. Check the consumables to insure they
are producing a stable arc. Replace Consumables and insure you
have the proper PSI at the regulator.

Inconsistent
Arc

Improper grounding or possible lack of air pressure. Check and

replace consumables and adjust the regulator to proper PSI

Plasma Cutter
Pilot Does not
Ignite

Check consumables to insure they are super tight. Possibly,

replace the tips. Insure that you have compressed air flowing to the
unit. Drop the PSI pressure.

O.C. Over
Current LED
Lights

The unit has reached its DUTY Cycle. Leave power of the

machine on and allow fans to cool the machine. You can also turn
the machine off to properly cool it. Do not continue to weld until
light is off.

Issue Not Listed

Contact LONGEVITY Toll Free 1-877-566-4462 or via email at

[email protected]