Operation, care, and cleaning of your ice machine – MARVEL Scientific 6ADi User Manual

Page 14

Advertising
background image

OPERATION, CARE, AND CLEANING OF YOUR ICE MACHINE

Operation (Turning on the ice machine)

Once the drain and water supply are hooked up, and the ice

machine is in place and leveled plug in the service cord. The ice

machine is shipped with the selector switch in the “OFF” posi-

tion. Place the switch to the “ON” position to turn on the ice

machine. The switch is located in the front grille, see 14 Figure

15 for location.

Your ice machine is unique in how it forms ice with fractional

freezing to form a slab of ice that is clear and has less mineral

content than the water it is produced from. This is accomplished

by running water over the cold evaporator plate which gradually

freezes the water to produce the ice slab. Mineral deposits are

left in the reservoir.

When the ice slab reaches the correct thickness determined by

the temperature of the evaporator plate, the electronic control

switches to the harvest cycle to harvest the ice. During the

harvest cycle, the ice slab falls from the evaporator to the ice

grid cutter. Here, the ice slab is cut into 3/4” squares by the grid

cutter’s heated wires. During the harvest cycle, the drain valve

will remain open for 45 seconds to drain the reservoir of remain-

ing deposits. After that, the water valve will open for two (2)

minutes providing two (2) quarts of water to the reservoir for the

next production cycle.

The ice machine will keep producing ice until the ice machine’s

bin is full and will restart automatically when ice needs to be

replenished in the bin.

Care of the Ice Machine

1. Avoid leaning on the cabinet door. You may bend the door

hinge or tip the unit.

2. Exercise caution when sweeping, vacuuming or mopping

near the front of the unit. Damage to the grille and/or

switch can occur.

3. Periodically clean the inside of the ice machine components

and inside of the unit.

4. Periodically check and/or clean the front grille and condens-

er coils as needed.

5. If your ice machine has either a stainless steel door and/or

cabinet, to keep it looking its best, we recommend periodi-

cally applying a stainless steel cleaner and a non-abrasive

stainless steel polish. This is especially important for

outdoor applications and locations near salt-water environ-

ments.

Cleaning the Ice Machine

Some impurities will remain and build up in the ice machine and

stick to the ice machine’s parts over time. This build-up must be

removed for proper ice production, ice quality, and ice machine

life. Your ice machine is equipped with a cleaning mode that will

help in cleaning out these impurities.

The impurities will need to be cleaned of this build-up regularly

(at the very least, annually), depending on use and water hard-

ness. Use a nickel safe ice machine cleaner, including but not lim-

ited to the following brands. Ice machine cleaners are available

at most appliance retailers or through the cleaner manufacturers

website.

Kirby’s Certified ice machine cleaner, 100% nickel safe.

Nu-Calgon nickel safe ice machine cleaner.

Franklin Machine Products nickel safe ice machine cleaner.

To clean the ice machine:

1. Switch the selector switch to the “OFF” position.

2. Remove the drain plug at the bottom of the reservoir to

drain any remaining water and then reinstall.

3. Access to the reservoir can be obtained by removing the

front panel screws and the front panel. Determine the

proper amount of cleaner from the ice machine cleaner

manufacturer’s mixture ratio based on three (3) quarts

of water (refer to the manufacturer’s directions). Add the

recommended cleaning solution to the reservoir of the ice

machine.

4. Replace the front cover panel and close the door.

5. Switch the selector switch on the grille of the ice machine to

the “CLEAN” position. Three (3) quarts of water will auto-

matically be added to the cleaning solution.

6. The total cleaning time will end in 49 minutes. The clean-

ing cycle will automatically rinse the evaporator plate and

also drain the cleaning solution and rinse the reservoir with

water.

7. After the cleaning cycle has ended, remove the front panel

again and check that the build-up has been removed. The

evaporator plate should be clean, shiny, and smooth to the

touch. If build-up is still visible, repeat the cleaning cycle

above. If build-up is removed, continue below.

8. Remove the distributor tube, hose clamp, hose and its rubber

ends.

9. Thoroughly clean the inside of the distributor tube and the

spray holes. You can use the same cleaning solution as

before and an old toothbrush to reach the inside of the

distributor tube.

10. Reinstall the rubber ends, hose, and hose clamp to the

distributor and then reinstall the distributor tube to the

evaporator with the spray holes pointed to the bottom of the

evaporator plate. Reinstall the front cover panel with the

two (2) front panel screws.

Rubber ends

Spray Holes

Figure 14

Distributor tube

14

Advertising
This manual is related to the following products: