Billion BIPAC-8500 / 8520 SHDSL VPN Firewall Bridge / Router

Chapter 5: Troubleshooting

Frequent loss of

SHDSL linesync

(disconnections).

Ensure that all other devices connected to the same telephone line as your

Billion router (e.g. telephones, fax machines, analogue modems) have a

line filter connected between them and the wall socket (unless you are

using a Central Splitter or Central Filter installed by a qualified and

licensed electrician), and ensure that all line filters are correctly installed

and the right way around. Missing line filters or line filters installed the

wrong way around can cause problems with your SHDSL connection,

including causing frequent disconnections.

Problems with the LAN Interface

Problem

Corrective Action

Can’t ping any PCs on

the LAN.

Check the Ethernet LEDs on the front panel. The LED should be on for a

port that has a PC connected. If it is off, check the cables between your

router and the PC. Make sure you have uninstalled any software firewall

for troubleshooting.

Verify that the IP address and the subnet mask are consistent between the

router and the workstations.