Post frame building details – Metal Sales Pro-Panel II Installation User Manual

Page 32

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice / Effective 5/09.

31

POST FRAME

& RESIDENTIAL

POST FRAME BUILDING DETAILS

GABLE TRIM DETAIL

RAKE TRIM DETAIL

UNIVERSAL SIDEWALL DETAIL

UNIVERSAL ENDWALL DETAIL

ROOF PANEL

STITCH SCREW

(EVERY RIB*)

OUTSIDE CLOSURE

TAPE SEALANT

TAPE SEALANT

FASTENER

GABLE TRIM

ROOF PANEL

STITCH SCREW

(EVERY RIB*)

OUTSIDE CLOSURE

STITCH SCREW

(1'-0" O.C.)
TAPE SEALANT

TAPE SEALANT

FASTENER

GABLE TRIM

WALL PANEL

ROOF PANEL

INSIDE CLOSURE

FASTENER

TAPE SEALANT

UNIVERSAL SIDEWALL

STITCH SCREW

(EVERY RIB*)

INSIDE CLOSURE

FASTENER

TAPE SEALANT

UNIVERSAL ENDWALL

OUTSIDE CLOSURE

WALL PANEL

STITCH SCREW

(1'-0" O.C.)

ROOF PANEL

STITCH SCREW

(1'-0" O.C.)

* FASTENER SPACING TO BE 8" - 12" O.C.

* FASTENER SPACING TO BE 8" - 12" O.C.

* FASTENER SPACING TO BE 8" - 12" O.C.