DETERMINING THE LOCATION FOR DV1000

Note: The installation must conform with local codes or, in the absence of local codes, with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54,
or the Natural Gas and Propane Instal-
lation Code, CSA B149.1.

This appliance may be installed in an aftermarket, permanently located, manufactured
home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appli-
ance is not convertible for use with other gases, unless a certified kit is used.

Due to high temperatures, the appliance should be located out of traffic and away from fur-
niture and draperies.

The appliance, when installed, must be electrically grounded in accordance with local codes
or, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70,
or the
Canadian Electrical Code CSA C22.1.

The Model DV1000 Direct Vent Fireplace must be vented using only Magnaflex DV4-F venting
system. All warranties will be voided and tech service suspended and serious fire, health or
safety hazards may result from using any other venting system than the tested and approved
Magnaflex DV4-F system with this appliance.

You must check the Vent Termination Clearance requirements from decks, windows, soffits, gas
regulators, air supply inlets, and public walkways, etc. as shown in these instructions and speci-
fied by local building codes (see figure 4, page 7). This gas appliance must be vented directly to
the outside of the building. This gas appliance must not be connected to a chimney flue serving a
separate solid-fuel burning appliance. Preparation for electrical connection and gas supply must
be made before the appliance is located. (see figure 3, page 6 for framing dimensions)

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL FROM FIREPLACE AND
VENT SURFACES:

Sides, Back, Bottom and Top of appliance (standoffs) 0 inch
Recessed depth to back of front trim 17 inches
Recessed depth to front of front trim 17-1/2 inches
Diameter of vent pipe 2 inches
Top of appliance to ceiling 54 inches

MANTEL CLEARANCES……

STANDOFF

DV1000

STUD

WALL BOARD

DRYWALL

H

TOP EDGE OF
UNITS TRIM

W

W=Width (@) H=Height

3/4” ——————–2”
2”———————–2”
4”———————–10”
6”———————–12”
8”———————–14”
10”———————16”
12”———————18”

FIGURE 5

NOTE: Adequate clear-
ances around air openings
into the combustion cham-
ber. Do Not cover any of
the louvered areas on this
appliance front, or the glass
cover door.