New Buck Corporation DV1000 User Manual

Page 5

Advertising
background image

INTRODUCTION AND SAFETY FOR

INSTALLATION AND OPERATION

This instruction manual will help you obtain a safe, efficient, dependable installation for your appliance
and vent system. Please read and understand these instructions before beginning your installation.

The model DV1000 is a sealed combustion, air circulating gas appliance designed for residential and
mobile home applications. The appliance must be installed with Magnaflex DV4-F

vent system that is

routed to outside atmosphere. It is also listed for bedroom installations.

This appliance is designed to operate on natural or propane gas. A millivolt gas control valve with piezo
ignition system provides safe, efficient operation. No external electrical power is required to operate the
gas valve and burner. 115V AC is required to operate the room air fan.

This appliance complies with National Safety Standards and is tested and listed to ANSI Z21.88-2005
and CSA 2.33-2005
.

Installation must conform to local codes. In the absence of local codes, installation must comply with
the current

National Fuel Gas Code, ANSI Z223.1/NFPA54, or the National gas and Propane

Installation Code, CSA b149.1..

.

“WARNING”: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage.

SPECIFICATIONS - MODEL DV1000

RATE:

NAT.

L.P.

MAX.

25,000

BTU

24,000

BTU

MIN.

20,000 BTU

20,000 BTU

GAS SUPPLY PRESSURE: NAT.

L.P.

MAX. INPUT

10.5" W.C.

13.0" W.C.

MIN. INPUT

*4.0" W.C.

11." W.C.

MANIFOLD PRESSURE: NAT.

L.P.

3.5"

W.C.

10.0"

W.C.

EFFICIENCY:(With Blower “ON”)

NATURAL

GAS

88%

L.P. GAS

88%

FLUE VENT

4" INNER, 7" OUTER; Magnaflex

SAFETY

CSA

CERTIFIED

PILOT GENERATOR, MILLIVOLT

SYSTEM

ACTIVATED

WITH SWITCH OR THERMOSTAT.

“WARNING”: This appliance must not be connected to a chimney flue serving a separate
solid-fuel burning appliance.

“Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system
and any gas control which has been under water.”

NOTE: the appliance are be kept clear and free from combustible materials, gasoline and
other flammable vapors and liquids.

The flow of combustible and ventilation air not be obstructed.

Page 2