Ul f

ire

r

esisTanCe

r

aTings

METAL SALES MANUFACTURING CORPORATION

R9697

Mechanically attached metal roof panels - Type “Vertical Seam” secured by steel anchor clips.

Anchor clips are attached to a hat shaped member* (minimum depth 1 in.) or a bearing plate**.

For use in Design Nos. P224 , P225 , P227 , P230 , P237 , P508 , P510 , P512 , P701 , P711 , P712

, P713 , P715 , P717 , P720 , P722 , P723 , P724 , P726 , P731 , P734 , P736 , P803 , P814 , P815 ,

P818 , P819 , P821 , P823 , P824 .

*Hat shaped member to be a minimum of 16 gauge. The member will be fastened through the roof

insulation to the steel roof deck with min. No. 14 self-drilling and/or self-tapping fasteners. Spacing

to be determined by the structural loading requirements. In addition any compressible UL Classified

glass fiber blanket insulation with or without a vapor retarder facing may be used between the speci-

fied roof insulation and the metal roof panels.

**Bearing plate to be a minimum of 16 gauge. Member will be fastened through the roof insulation to

the steel deck with min. No. 14 self-drilling and/or self-tapping fasteners.

See the UL Fire Resistance Directory for explanation of each design number listed above.

Underwriters Laboratories Inc.

®

UL

®

LISTED

PVS-13

VERTICAL SEAM

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11