Construction No. 255

January 30, 2002

Uplift - Class 90 and 60

(See Item No. 4)

Fire Not Investigated

1. Metal Roof Deck Panels* No. 24 MSG min thickness coated steel. Panel width 18 in. max., 10 in. min. Rib height 1-3/4

in. at female side. Panels continuous over two or more spans. A bead of sealant may be used at panel side joints.

METAL SALES MANUFACTURING CORPORATION - “Vertical Seam”.

2. Roof Deck Fasteners* (Panel Clips) - One piece assembly, 3-1/2 in. wide, 1-7/8 in. high. One panel clip located at each

purlin intersection.

METAL SALES MANUFACTURING CORPORATION - “Vertical Seam Clip”.

3. Panel Fasteners (Screws) Fasteners used to attach panel clips (Item 2) to purlins to be No. 10-16 by 1 in. long plated

pancake head No. 2 phillips drive, No. 3 self-drilling point steel screws. Two screws per clip to be used inserted through 1/4

in. diam guide holes.

4. Purlins No. 16 MSG min thickness steel (50,000 psi min yield strength).

Spacing for Class 90 to be 48 in. OC: For Class 60 to be 60 in. OC

Refer to General Information Roof Deck Constructions for items not evaluated.

*Bearing the UL Classification Mark

Underwriters Laboratories Inc.

®

UL

®

LISTED

PVS-7

VERTICAL SEAM

© Metal Sales Manufacturing Corporation/ Subject to change without notice/ Effective Date 9/11