Model 512.04 Hydraulic Power Unit

10

Introduction

Specifications

Model 512.04 Specifications

P

ARAMETER

S

PECIFICATION

Environmental

Operating temperature
(ambient air)

Heat load

*

Noise rating

at 1 m

18–49°C (65–104°F)

1061 kcal/hr (4200 BTU/hr)

74 db (A)

Pump

Flow capacity
at 13.8 MPa (2000 psi)

Motor rating

Operating voltage

12.5 lpm (3.3 gpm) @ 50 Hz
15.1 lpm (4 gpm) @ 60 Hz

3.7 kW (5.0 hp)

208 V (ac) @ 16.7 A, 3 phase
230 V (ac) @ 15.2 A, 3 phase
460 V (ac) @ 7.6 A, 3 phase

Hydraulic fluid

Nominal temperature

Filtration (microns)

Reservoir capacity

Mobil DTE 26

®

or Shell Tellus

®

26

63°C (145°F)

3 µ absolute

57 liters (15 gallons)

Heat exchanger

Flow requirements

Water pressure
(differential)

Max input pressure

Cooling

Water hose

Water cooled or air cooled

13 lpm @ 21°C (3.5 gpm @ 70°F)

0.2 MPa (30 psi)

1 MPa (150 psi)

3276 Kcal/hr (13,000 BTU/hr)

12.7 mm (0.5 in)—inside diameter

Hydraulic connections

Pressure
Return
Drain

each requires a 37° flare

-8
-8
-6

Weight

115 kg (250 lb)

*