Electronics
The HPU has basic controls to turn it on to low pressure or high pressure
and to turn it off. The HPU includes an
Emergency Stop
switch that is
connected to the interlock chain of your test system.
A hydraulic interlock can be generated by the hydraulic power supply if
one of the following occurs:
•
Low hydraulic fluid level
•
High hydraulic fluid temperature
•
Dirty hydraulic power supply filter (optional)
Hydraulic
schematic
The hydraulic schematic shows how the hydraulic components are
connected in the Model 512.04 Hydraulic Power Unit. Both types of heat
exchangers are shown.
Return -8
37
° JIC Flare
Pressure -8
37
° JIC Flare
Drain -06
SAE
0.125
1/2 NPT
Strainer
Pressure
Gage
Motor
Pump
Low Fluid
Switch
See Heat
Exchangers
Pressure
Relief
Valve
0.7–14 MPa
(100–2000 psi)
Fan and Motor
Air-Cooled Heat
Exchanger
Water In
1/2 ID Hose
Water Out
1/2 ID Hose
Water-Cooled
Heat Exchanger
High/Low
Pressure
Solenoid
Filter
Check
Valve
Overtemperature
Switch
Reservior