Model 293.32 hsm electrical connections – MTS Model 293-32 Hydraulic Service Manifold User Manual

Page 38

Advertising
background image

Description

Item

-06 Drain in (3)

8

-06 Pilot Pressure out

9

06 Hydrostatic bearing 1

10

-32 Pressure out to actuator

11

-32 Return in from actuator

12

Model 293.32 HSM Electrical Connections

The Model 293.32 HSM is equipped with a control manifold that permits selection of various hydraulic
pressures. Control cable connections must be made between the high and low solenoids of the HSM and
the system controller. The following figure shows the locations of the high/low solenoids on HSM.

High/Low Solenoid Locations

Description

Item

Pilot Pressure Accumulator

1

Main Filter

2

Pressure Gage

3

Control Manifold

4

38 | Model 293.32 Hydraulic Service Manifold