20. Align the front door latch.

a) Loosen the top and bottom M4 flathead screws located inside the door latch vertical edge.

b) Adjust the latch so that the upper and lower catch ball bearings touch the latch simultaneously. You

can view this from the side.

c) Slightly tighten the two screws loosened in step 20a such that the latch is somewhat secure.

d) Close and open the door two or three times to allow the latch to align exactly with the catch ball bearings

on the side panel.

e) Fully tighten the two screws loosened in step 20a.

21. Remove the protective covering from the panels and door.

Install MTS Acumen Test Area Enclosure
(Left-Hand Opening)

The test area enclosure is shipped configured with the right hand door opening (hinges on the left). If your layout
requires a left-hand door opening, you will first need to install the enclosure as shipped (steps 1 through 12) and
then change the door opening orientation (the remainder of this procedure).