Damper System Operation

16

Interlocks

Introduction

Interlocks

The test controller incorporates interlock circuitry that can automatically stop a
test when a system problem, specimen failure, or an operator error could result in
unwanted or unexpected actuator movement. The test controller interlock
circuitry will cause one of two interlocks to occur in response to specific
conditions encountered during testing. These interlocks are:

Hydraulic Interlock – stops the program and removes hydraulic pressure
from the system.

Program Interlock – stops the current test program when certain test
parameters are not met or are exceeded.

The following table lists the possible types of interlock conditions for the test
controller.

Condition

Cause

Type of Interlock

Emergency Stop

Emergency Stop or E-Stop button pressed

Hydraulic

Program Aux

Open circuit at the Prog Intlk rear panel connector

Program

Hydraulic event

Fault in the performance of hydraulic components

Hydraulic

Mechanical event

Fault in the performance of mechanical components

Hydraulic

End-of Count

Completion of a preset number of cycles in the current test
program

Hydraulic or
Program

Underpeak

Selected signal fails to reach a preset minimum or maximum
level

Hydraulic with

indicator option

*

*

These interlocks can be set to indicate only. For further information on configuring these interlocks,
refer to the test controller documentation.