Specifications

Series 256 Servovalve Product Information

Introduction

17

Specifications

The following subsections list the general specifications, performance
specifications, and performance characteristics of the Series 256 Servovalve.

Series 256 Servovalve General Specifications

The following table shows the specifications that are common to all Series 256
Servovalves.

P

ARAMETER

S

PECIFICATION

Temperature range

-54°C to +135°C (-65°F to +275°F)

Operating pressure*

Maximum

Minimum

The normal operating pressure is 21 MPa (3000 psi)

21 MPa (3000 psi)

1.3 MPa (100 psi)

Recommended hydraulic fluid

Pilot stage filtration

Main stage filtration

Mobil DTE 25 or Shell Tellus 46

3 microns absolute

12 microns absolute

Seals

Buna-N Standard

LVDT

Excitation

Impedance

Sensitivity

.

20 V p-p at 10 kHz

200 ¾ minimum at 10 kHz

0.21 V/V per 2.54 mm (0.100 inch) stroke

Pilot stage full flow current

25 mA (series)
50 mA (differential)
50 mA (parallel)

Weight

256.04-01
256.05-01/02
256.09-01/02
256.18-01/02/05
256.25-01/02/05
256.40-01/02/05/10

6.3 kg (14 lb)
7.3 kg (16 lb)
7.3 kg (16 lb)
9.3 kg (12 lb)
20.4 kg (43 lb)
45.4 kg (100 lb)

* Higher operating supply pressures up to 41 MPa (6000 psi) are available on request (contact MTS for

information.

† Special seals are available on request on some 256 Models (contact MTS for information).