18

Specifications

Introduction

Static Performance Specifications

Values are typical for Series 256 Servovalves operated at the recommended
hydraulic fluid filtration levels.

Dynamic Performance Specifications

The dynamic data is derived from typical Model 256 Servovalve driven with a
valve controller with “rate” compensation. A constant amplitude sine wave was
used as the input signal to the valve controller. The amplitude was plus-or-minus
the main stage, full-stroke, and LVDT voltage.

M

ODEL

*

R

ATED

F

LOW

N

OMINAL

G

AIN

P

RESSURE

G

AIN

P

RESSURE

C

OEFFICIENT

N

ULL

F

LOW

L/

MIN

GPM

L/

MIN

/

%

STROKE

GPM

%

STROKE

(%

SUPPLY

/

%

STROKE

)

CM

3

/

KGF

-

SEC

IN

3

/

SEC

/

PSI

)

L/

MIN

GPM

256.04

150

40

2.2

0.58

100

0.30

1.3x10-3

9.5

2.5

256.09

340

90

6.0

1.6

150

0.56

2.4x10-3

13.0

3.5

256.18

680

180

10.6

2.8

200

0.73

3.1x10-3

21.0

5.5

256.25

950

250

16.0

4.2

160

1.38

5.9x10-3

23.8

6.3

256.40

1500

400

29.0

7.7

250

1.38

6.9x10-3

20.4

7.5

M

ODEL

*

R

ATED

F

LOW

P

ILOT

F

LOW

F

ULL

F

LOW

F

REQUENCY

90º P

HASE

S

IGNAL

S

POOL

S

TROKE

R

ISE

T

IME

(T

R

)

(

MILLISECONDS

)

L/

MIN

GPM

L/

MIN

GPM

H

Z

H

Z

90% O

PEN

10% O

PEN

256.04A-01

150

40

3.8

1

80

130

4.8

3

256.09A-01
256.09A-02

340
340

90
90

3.8
9.5

1
2.5

30
80

120
130

9
4.6

3.5
4.3

256.18C-01
256.18C-02
256.18C-05

680
680
680

180
180
180

3.8
9.5
19

1
2.5
5

20
30
50

90
100
100

12
7
5.5

3
2.2
1.8

* Performance information is provided for the models listed. Contact MTS for performance information

for Models 256.18D and 256.xxB.

† At 10% spool stroke.
‡ These are estimated values. All other values are typical.

Advertising