Troubleshooting (engine/mixer) – Multiquip WM45H User Manual

Page 25

Advertising
background image

WM45H/e pLaSTeR MORTaR MIXeR • OpeRaTIOn and paRTS ManuaL — Rev. #0 (09/27/12) — page 25

Practically all breakdowns can be prevented by proper

handling and maintenance inspections, but in the event

of a breakdown, please take remedial action following

the diagnosis based on the Troubleshooting Tables If the

problem cannot be remedied, please leave the unit just as

it is and consult or company's service department.

trOublesHOOtinG (enGine/Mixer)

Troubleshooting (Mixer)

Symptom

possible problem

Solution

Blades will not rotate.

Worn or defective V-belt?

Replace V-belt.

Adjustment lever mis-aligned?

Check position of adjustment lever.

Adjust if necessary.

Material load too heavy, exceeding

mixer capability?

Reduce amount of material being

mixed.

Object stuck inside mixing drum,

jamming paddle rotation?

Stop engine. Empty out drum

contents. Remove obstruction.

Improper engine speed?

Check and adjust engine speed.

Material leaking from drum ends.

Worn or defective paddle shaft seals? Replace seals.

Drum diffi cult to discharge (tilt).

Defective or worn drum support

brackets?

Apply grease to bracket or replace.

Blades adjusted too tight.

Adjust blades until they almost touch

side walls of drum.

Troubleshooting (electric Motor)

Symptom

possible Cause

Solution

Electric motor will not start.

Is there power?

Check power source. Check reset

button.

Is power cable plugged in?

Plug in power cable.

Is ON/OFF switch placed in ON

position?

Place ON/OFF switch in ON position.

Defective electric motor ON/OFF

switch?

Replace switch.

Defective motor windings?

Repair windings or replace windings.

Defective extension cord?

Replace extension cord.

Electric motor continuously stops.

Reset button OK?

Check power source.

Electric motor RPM's too low.

Low voltage?

Check input voltage.

Electric motor RPM's too high.

High voltage?

Check input voltage.

Advertising