Actuator module components, Metering air valve maintenance, Adjust air valve meter time – Bradley Smoker Terreon TDB3104 User Manual

Page 25: Tube connection leaks

Advertising
background image

Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve

Installation Instructions

TDB3104, WF3204

Bradley Corporation • 215-1470 Rev. H; EN 06-915

25

2/8/07

Screw (160-165)

Spring * (135-065)

Piston * (119-227A)

U-Cup * (125-099)

Pushbutton
Assembly
(S08-324)

Nut (110-115)

Actuator Body * (118-279)

Duckbill Check * (198-010)

Actuator Bracket (140-743)

Straight Tube Connector * (169-890)

Actuator Module Components

* Included in Actuator Assembly S65-168

Metering Air Valve Maintenance

Adjust Air Valve Meter Time

NOTE: The air valve timer is located next to the tube connector
on the air valve body. The timer is capped with a filter to prevent
dirt build-up on the timer. The air valve timing can be adjusting
from 5–60 seconds.

1. Remove filter cap and use a screwdriver to tighten or

loosen the timer (see illustration at right). Turning the
timer clockwise increases the time; turning the timer coun-
terclockwise decreases the time.

2. Continue to adjust until the timer is set at desired length.

3. Replace filter cap over the timer.

Tube Connection Leaks

1. Push in the white manual release button while pulling the

tube out (see illustration at right) to disconnect the tube at
the connector. No tools are needed.

2. To correct a leak, press tubing firmly into the connector

and make sure it is seated.

3. If leak persists, remove tubing from the fitting, and trim

the tubing end square with a razor-sharp knife. If leak con-
tinues, replace the fitting or contact your Bradley represen-
tative for assistance.

AIR VALVE

WATER TUBE CONNECTOR

FILTER CAP

AIR TUBE