LT12Dab LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #0 (06/03/11) — page 27

TuRnIng On THe LampS

The main circuit breaker (30 amps), and 4 lamp circuit

breakers (15 amps each) are located on the upper control

panel (Figure17).
1. Place the main circuit breaker (Figure 17) on the control

panel to the ON position.

Figure 17. Control Panel Circuit Breakers

2. Set lamp circuit breaker #1 on the control panel to the

ON position.

3. Wait a few minutes for the ballast to activate. Observe

that lamp #1 is ON.

4. Repeat steps 2 and 3 for lamps 2 through 4.
5. If all the lamp circuit breakers are in the ON position

(up), then all of the lights should be on.

6. If any of the lamps are not on, refer to the troubleshooting

section of this manual.

7. Close all cabinet doors.

AUXILIARY

RECEPTACLE

CIRCUIT

BREAKER

LAMP

CIRCUIT

BREAKERS

MAIN

CIRCUIT

BREAKER

LIGHT CONTROL/BREAKER

15A

AUX

BREAKER

30A

MAIN

BREAKER

NOTICE

neveR operate the light tower with the engine

compartment doors open. Operation with the doors

open may cause insufficient cooling to the unit, and

damage may result.

auXILIaRY OuTpuT ReCepTaCLeS

The light tower is equipped with auxiliary output receptacle

wiring ready to install auxiliary receptacles (Figure 18).

Figure 18. Auxiliary Output Receptacles

DOCUMENTATION

BOX

FRONT

VIEW

AUXILIARY

OUTPUT

RECEPTACLES

15 AMPS

DangeR

neveR grab or touch a live power cord

with wet hands. The possibility exists

of electrical shock, electrocution, and

even death!

OperatiOn