Operation – Multiquip LT12DAB User Manual

Page 28

Advertising
background image

page 28 — LT12Dab LIgHT TOWeR • OpeRaTIOn manuaL — Rev. #0 (06/03/11)

nORmaL SHuTDOWn

1. If a load is attached to the generator of the light tower,

remove the load.

2. Set the four lamp circuit breakers on the control panel

to the OFF position.

3. Place the MAIN circuit breaker on the control panel to

the OFF position.

4. Wait a few seconds and observe that all four lamps

are OFF.

5. Let the engine idle for a few minutes with no load.
6. Turn the ignition key to the OFF position. Store key in

a safe location.

7. Lower light tower mast and place in stow position as

outlined in this manual.

8. Place outriggers in tow position, and remove chock

blocks.

9. Store light tower in a clean, dry location out of the reach

of children and unauthorized personnel.

emeRgenCY SHuTDOWn

1. Turn the ignition key to the OFF position and turn all

circuit breakers to the OFF position.

NOTICE

Failure to turn the breakers off may damage the

generator.

NOTICE

If servicing is required, allow lamps to cool for about

15 minutes before removing lamps.

OperatiOn

Advertising