Maintenance

CE

Fig. 8

The BB 200 is to be lubricated from time to time. Fig. 8

Kindly refer to the table below for the quantities of grease and

the lubrication intervals.

The lubrication points are marked with red dots on the unit.
No.

Quan. in kg

Interval, hours of operation

1

0.008

50

2

0.008

50

The points not shown in Fig. 8 but indicated with arrows are

permanently lubricated.
Use the grease gun supplied with the BB 200 for lubrication

purposes.

Ordinary multi-purpose graese can be used as lubricant, e.g. EP

4685 by ESSO / SHELL or BP.

Functional inspections

The limit switch at the fill hopper is to be checked semiannually

for proper functioning. Fig. 9
*

Open the toggle clamp F on the filling hopper B.

*

Pull back the filling hopper.

*

The BB 200 stops completely.

*

Pull down and close the filling hopper B.

The BB 200 must not start up again.
*

Close the toggle clamp F on the filling hopper B.

*

Start the BB 200.

Fig. 9

B

F

Advertising