Parts list – RKI Instruments 1017-01 User Manual

Page 15

Advertising
background image

Model 1017-01 Operator’s Manual

• 11

3.

Allow the Model 1017-01 to draw sample for one minute.

4.

Follow the directions in the controller’s operator’s manual for setting the span.

5.

Disconnect the sample tubing from the inlet fitting.

6.

Unscrew the regulator from the combustible gas calibration cylinder.

Returning to Normal Operation

1.

Reconnect the incoming sample line.

2.

Wait approximately one minute to allow the combustible gas reading to stabilize.

3.

Follow the instructions in the controller’s operator’s manual to exit the calibration
mode.

4.

Store the components of the calibration kit in a safe and convenient place.

Parts List

Table 4 lists replacement parts and accessories for the Model 1017-01.

Table 3: Parts List

Part Number

Description

06-1200RK

Sample tubing, 4 x 6 mm, specify length (used for internal plumbing)

17-2593RK

Brass tubing insert for .25” O.D. x .17” I.D. flexible tubing (used when flexible
tubing is connected to inlet or exhaust fitting)

17-2673RK

Front ferrule (for inlet and exhaust fittings)

17-2678RK

Back ferrule (for inlet and exhaust fittings)

30-1016RK

Pump, w/cable and connector

33-3050RK

MC filter w/cartridge & flow monitor (recommended for installation external
to Model 1017-01 in inlet line)

81-0002RK-01

Calibration cylinder, 50% LEL hydrogen in air, 34 liter

81-0002RK-03

Calibration cylinder, 50% LEL hydrogen in air, 103 liter

81-0007RK-01

Calibration cylinder, 50% LEL hexane in air, 34 liter

81-0012RK-01

Calibration cylinder, 50% LEL methane in air, 34 liter

81-0012RK-03

Calibration cylinder, 50% LEL methane in air, 103 liter

81-0076RK-01

Zero air calibration cylinder, 34 liter

81-0076RK-03

Zero air calibration cylinder, 103 liter

81-1001RK

Dispensing valve (with knob)

81-1054RK

Regulator (demand flow)

81-1126RK

Gas collection bag (2 liter)

HW-6213

Combustible gas sensor, plug-in type, LEL

Advertising