6 • 35-3010RK-03 Sample-Draw Detector

Carbon Monoxide Sensor

The carbon monoxide gas sensor is installed in the upper left side of the flow block. It has
4 pins which mate with sockets in the preamp circuit board.

Hydrogen Sulfide Gas Sensor

The hydrogen sulfide gas sensor position is located in the upper right side of the flow
block. In the 35-3010RK-03, the hydrogen sulfide gas sensor position in the flow block is
occupied by a dummy sensor.

Preamp Circuit Board

The preamp circuit is used to connect the CO sensor to the main circuit board and to
secure the sensor in the flow block. Two cables mate to the main circuit board: the one on
the left is for the CO sensor signal and the one of the right is for the H

2

S sensor signal.

Since the H

2

S sensor is replaced with a dummy plug in the 35-3010RK-03 the H

2

S sensor

signal cable carries no signal in this version of the 35-3010RK.

Main Circuit Board

Figure 3: Main Circuit Board

The main circuit board includes the interconnect terminal strip, sensor/transmitter
terminal strip, amp 1 circuit, amp 2 circuit, pump terminal strip, relay, and reset switch.

NOTE:

The flowmeter and status lights are mounted to the main circuit board but are
considered part of the flow system.

Test Point CAL + 2

Amp 1

(CO)

Zero

Span

Zero

Fail LED

Sensor/Transmitter

Terminal Strip

Pressure Switch

Reset

Switch

Pilot LED

Amp 2

(H2S)

Span

Test Point CAL + 1

Test Point CAL - 2

Test Point CAL - 1

AC Terminal
Strip Not Used

Interconnect Terminal
Strip

Low Flow Adjust

Flow Adjust Pot

Flowmeter

Pump Terminal Stip

Relay