61-1001RK-05 Combustible Gas Detector• 11

NOTE:

For convenience, leave regulator and calibration cup connected by the sample
tubing.

2.

When the controller display reading falls below the alarm points and then return the
controller to normal operation.

NOTE:

If you do not allow the gas reading to decrease below the alarm points, then
unwanted alarms may occur.

3.

Verify that the controller display reading decreases and stabilizes at 0 %LEL.

4.

Store the components of the calibration kit in a safe and convenient place.

Parts List

Table 3 lists replacement parts and accessories for the 61-1001RK-05 hydrogen detector.

Table 3: Parts List

Part Number

Description

18-0400RK-01

Junction box with spacers

NC-6205-05

Replacement hydrogen detector

71-0195RK

61-1001RK-05 Hydrogen Detector Operator’s Manual (this document)

81-0002RK-01

Calibration cylinder, 50 %LEL hydrogen in air, 34 liter steel

81-0076RK-01

Zero air calibration cylinder, 34 liter steel

81-1050RK

Regulator, 0.5 LPM with pressure gauge and flow control knob, for 17
and 34 liter steel calibration cylinders

81-1117RK

Calibration cup