65-2484RK Multi Point Detector • 35

NOTE:

Depending on the size of your zero air cylinder, it is possible that you will have a
different regulator for the zero air cylinder and toxic gas cylinder. If necessary to
fit the calibration toxic gas cylinder, change the regulator.

Setting the Response Reading

1.

Screw the regulator into the calibration gas cylinder.

2.

Follow the directions in the controller operator’s manual for setting the response
(span) reading.

3.

When the directions call for exposing the detector to gas, turn the regulator’s on/off
knob counterclockwise to open it. Gas will begin to flow.

4.

Allow the gas to flow to the detector for 2 minutes.

5.

Turn the regulator’s on/off knob clockwise to turn it off.

6.

Set the response reading according to the controller operator’s manual.

Returning to Normal Operation

1.

Unscrew the regulator from the cylinder and gently pull the calibration cup off of the
plug-in sensor.

NOTE:

For convenience, leave the regulator and calibration cup connected by the
sample tubing.

2.

Allow about 45 seconds for the gas reading to decrease below the alarm points and
then return the controller to normal operation.

NOTE

: If you do not allow the gas reading to decrease below the alarm points, then

unwanted alarms may occur.

3.

Verify that the controller display reading decreases and stabilizes at 0 ppm.

4.

Store the components of the calibration kit in a safe and convenient place.